connections. The single gang and double gang openings shall be for power
(standard electrical and for lighting equipment).
iii. The stage left and stage right audio plates shall have a Whirlwind W1
connectors wired in parallel to XLRs on the plate designated by the label on
the plate (see Plate Proofs below).
iv. All RJ-45 connections in plates shall be Neutrik CAT6 shielded Ethercon
connectors. All cable mount Ethernet connections shall be Neutrik NE8MC6-
MO connectors with color coded boots to match engraving around plate
mounted connectors for easy identification.
v. All cable mount speaker connectors shall be Neutrick NLT4FX connectors.
h. Rack System and Power
i. The rack shall be a Middle Atlantic 44sp ERK-44-25 rack with a VFD-44
vented front door and an ERK-4FT-285CFM fan top.
ii. The AV contractor shall provide appropriate blank panels to fill the front of the
rack as indicated on the rack elevation drawings
iii. Power in the stage rack shall be controlled by a Middle Atlantic USC-6R
controller. Power status shall be controlled by the Crestron Control System.
iv. The Electrical Contractor shall provide seven 30A circuits to the rack location.
The EC shall terminate the 30A circuits in the rack to the Middle Atlantic
RLM30 switched outlets.
v. The EC shall provide two 20A circuits to the rack location. The EC shall
terminate the 20A circuits is a duplex receptacle for each.
vi. Two Middle Atlantic PDC-915R-6 power strips will be connected to the two
20A circuits.
vii. All plate locations and conduit needs are specified in the AV drawings and the
Riser Wiring Worksheet attached to this document.
i. Clear Com System
i. A Clear Com MS-702 main station shall be mounted in the booth rack location
and provide intercom to all video patch plates, and dedicated intercom plates as
specified in the AV drawings. A Program Audio feed from the DSP will be
connected to the MS-702. The intercom system will provide two channels
(A&B) for all intercom locations.
ii. A Clear Com HB-702 will be mounted in the Green Room.
iii. All intercom plates will have a DPDT switch wired to a three pin XLR
providing the user to chose intercom channel A or B.
iv. The intercom beltpacks shall be RS601, qty 6.